Table 1 Performance comparisons of Rydberg atom-based electric field measurement enhancement using resonators. Ref.: reference, \(f_{0}\): center frequency, ES: electrical size, EF: enhancement factor, S: sensitivity

From: Local oscillator port integrated resonator for Rydberg atom-based electric field measurement enhancement

Ref.

\(f_{0}\)

LO port

S11

ES

EF

S

[26, 27]

4.35 GHz

No

no mention

0.435 λ

24 dB

no mention

[29]

1.309 GHz

No

no mention

0.096 λ

40 dB

5.5 \(\mu \text{V}/\text{cm}/\sqrt {\text{Hz}}\)

[30]

19.629 GHz

Yes

no mention

3.273 λ

7.9 dB

no mention

[34]

0.638 GHz

Yes

−0.1 dB

0.342 λ

34 dB

854 \(n \text{V}/\text{cm}/\sqrt {\text{Hz}}\)

This work

0.946 GHz

Yes

−38.2 dB

0.088 λ

32 dB

213 \(n \text{V}/\text{cm}/\sqrt {\text{Hz}}\)