From: Eliminating sensing blind spots of field-enhanced Rydberg atomic antenna via an asymmetric parallel-plate resonator
Reference
Volume dimensions[cm]
Rydberg probe efficiency
[33]
not mention
17%
[31]
45 × 60 × 120
[34, 35]
space optical paths
40.4%
Our work
45 × 45 × 15
41.0%